Friendo™ : Cordless Endodontic Vertical Condensation Pen

DXM Co., Ltd. · #EF-1110 · source

Product Features

  • Lightest cordless warm vertical condensation device reduces fatigue and increases precision
  • Effectively liquefies and condenses root canal filling materials
  • Excellent apical control over lateral and complicated root canals
  • 3 adjustable temperature settings (170 / 200 / 230 °C)
  • Color-coded pen tips available in various sizes (XF, F, FM, M, ML)

Cleaning Instructions

Hand Piece:
  1. Remove the hand piece from the charger.
  2. Thoroughly clean the surface of the hand piece by wiping with a soft cloth dampened with disinfection solution not containing phenols.
  3. Do not directly spray disinfection solution or disassemble any portion of the hand piece for cleaning.
Charger Base:
  1. Remove the hand piece from the charger and completely disconnect from power supply.
  2. Gently clean the surface of the charger by wiping with a soft cloth dampened with disinfection solution not containing phenols.
  3. Do not directly spray disinfection solution or disassemble any portion of the hand piece for cleaning.
Sterilization of Pen Tip:
  1. Make sure to remove all visible residue from the tip, then use thermo-disinfector to steam sterilize for cleaning (ultrasonic cleaner is recommended).
  2. Disinfect, clean and steam sterilize by using proper cleaning equipments after each use.
  3. New tips are not sterilized, and must be properly sterilized before use by autoclaving above 121°C (250°F) for 30 minutes and dry it for 30 minutes.
  4. Ensure to clean, sterilize and disinfect tips after each use.
Hand Piece Protector:

In a steam sterilization method: gravity displacement type, sterilization temp 121°C (250°F), Time: 30 minutes, Drying Time: 30 minutes

WARNING

Do not use nonvolatile guttapercha remover or similar cleaning solution. Permanent internal or external damage may occur when improperly cleaned.

Do NOT Use:

  • Glutaraldehyde
  • Lysol®
  • Ammonia complex
  • Denatured Alcohol
  • Phenol or phenolic cleaner
  • Iodine complex solutions

Precautions:

  • Do not use other pellet brands, MUST only use OUR BRAND.
  • Do not use expired pellets.
  • Replace all worn out/damaged Plunger Teflon Ring.
  • Squeeze out the leftover pellet after each use.
  • Clean thoroughly after each use.

Product Information

ManufacturerDXM Co., Ltd.
ChargingRequires specific adapter
CordlessYes
Device TypeCordless Endodontic Vertical Condensation Pen
Drying Time30 minutes
Power SourceRechargeable Battery
Pen Tip SizesXF, F, FM, M, ML
Safety FeatureHeating cycle limited to 3 seconds to prevent burns
Special CautionsMust be kept dry after sterilization, charge regularly
Sterilization Time30 minutes
Temperature Settings3 adjustable settings (170 / 200 / 230 °C)
Sterilization Temperature121°C (250°F)