Loocid BCP™ Standard
Loocid LLC · source
Loocid BCP™ Standard
Developed to Benefit Implants
The Loocid BCP innovative drill bit design was initiated based on clinical reports showing that after placement of dental implants a critical healing period of 3-4 weeks exists. In this period, decreased implant stability, potential complications, and even failures have been reported. Surgical trauma, after implant bed preparation, results in bone resorption and remodeling that may affect healing times and osseointegration. This can be a significant problem when advanced treatment protocols, such as immediate function or immediate loading are used.
Based on these clinical findings, the Loocid BCP technology was developed featuring bone cell protection paired with high clinical efficiency.
The clinical goal of Loocid BCP is a high level of implant stability through minimizing trauma and maximizing efficiency for every implant osteotomy.
Safety Advantages
Bone Cell Protection
Bone cell protection through specific drill design and thermal control (Patent Pending)
Significantly lower temperatures during implant bed preparation compared to conventional pilot and bone drill bits
Loocid BCP™ Standard Drill
Loocid BCP™ Standard shows significantly lower temperatures in in-vitro studies compared to conventional pilot drills. A mild temperature increase, without bone cell damage, can activate the bone formation process.
Non-Loocid Conventional Drill
A pilot drill can generate excessive heat during implant bed preparation. Temperatures over 70 °C create immediately evident bone cell death. Over a period of weeks, a wider zone of necrotic bone develops around the implant which can prevent proper bone healing and can impede osseointegration.
Efficiency Advantages
Small cutting tip for an efficient & easy start without chatter and vibration
Multiple level cutting edges provide smooth and effortless drilling
Efficient and precise osteotomies with reduced drilling protocol
The 1-Drill Protocol™ results in optimized osteotomies when compared to conventional sequential drilling techniques
High primary stability: With the Loocid 1-Drill Protocol™, implant stability is increased up to two fold.
1-Drill Protocol™
Complete implant bed preparation in 8-12 seconds, with only one Loocid BCP™ drill bit
2 (or more)-Drill Protocol™
A narrow diameter Loocid BCP™ drill as the starter, followed by the final drill bit of preferred implant system
Product Information
| Manufacturer | Loocid LLC |
|---|---|
| Protocol | 1-Drill Protocol™ - Complete implant bed preparation in 8-12 seconds with only one Loocid BCP™ drill bit |
| Cutting Edges | Multiple level cutting edges provide smooth and effortless drilling |
| Design Features | Small cutting tip for efficient & easy start without chatter and vibration |
| Primary Stability | Implant stability increased up to two fold with the Loocid 1-Drill Protocol™ |
| Temperature Control | Significantly lower temperatures during implant bed preparation compared to conventional pilot and bone drill bits |
| Bone Cell Protection | Specific drill design and thermal control (Patent Pending) |
| Osteotomy Preparation | 8-12 seconds complete implant bed preparation |