Novo Pro 29L Plus
Ningbo Joident Electronics Technology Co., Ltd · source
Modeling
Combining the experience of modern art and minimalist shape design, it is seamless from inside to outside. Our design size can be used for any occasion, so that you can experience the charm of modern art.
Designed to make your life easier, save space and guarantee high efficiency
Intelligent monitoring and diagnosis system
Ensures a constant control and monitoring of the whole operating system of the sterilizer. When faults occur, it will find the failure parts sectionally, and shows the fault message and simple solution direct which makes the after-sales message is more detailed and the maintenance is more convenient. This device behaves like a "real technician" with real-time diagnostic and intervention capability.
Simplified traceability
The data of every sterilization cycle are traceable, in compliance with the applicable standards in force, thanks to the SD card Log or thermal printer (Built-in/External).
Pre-heating system
Preheating system with stand-by for minimum temperature maintenance and consequent time reduction of all the sterilization cycles.
Wind cooling super window
260x142mm large cooling area, 73 layers heat radiating aluminium sheet, 18 radiating pipe, to ensure the hot steam water changes to the cold water in a few seconds.
About Novo Pro
Sterilizers and accessories that help dentists and their assistants to always ensure the highest levels of safety and hygiene in their practice, in full compliance with applicable international regulations. Assures to sterilise unwrapped solid tools and porous products, small pourous items, pots and containers, single-wrapped or multiple-layer wrapped products.
Only three clicks, automatically complete sterilization cycle
Multi-language operating system
Intelligent diagnosis system
11 Programs and tests
Accurate touch interface Simplicity Innovation Practically
Completely Automatic Cycles
All Programs are completely automatic and all phases are managed by advanced card equipped with a powerful microprocessor. Each phase (vacuum, preheating, exposure time, drying) is monitored, backed up and managed automatically. There is no human intervention in cycle operation.
Solid load
Temperature (°C):134℃ Cycle type:S Sterilization time:10min Drying time:9min
Quick
Only for emergency sterilization of solid equipment (fabric not)
Temperature (°C):134℃ Cycle type:S Sterilization time:4min Drying time:4min
Hollow bodies
Solid and hollow load, cotton fabric
Temperature (°C):134℃ Cycle type:B Sterilization time:5min Drying time:18min
Multiple wrapping
Cotton fabric, wrapping equipment, hollow load
Temperature (°C):134℃ Cycle type:B Sterilization time:18min Drying time:18min
Pre-set programs
Programs are factory pre-set and all of them guarantee a perfect and safe sterilization of treated materials.
Solid load
Solid instruments
Temperature (°C):121℃ Cycle type:S Sterilization time:30min Drying time:9min
Glass
Glass instruments
Temperature (°C):121℃ Cycle type:S Sterilization time:20min Drying time:9min
Hollow bodies
Low temperature textile, wrapping equipment, mixed loading (packaging/ non packaging)
Temperature (°C):121℃ Cycle type:B Sterilization time:20min Drying time:18min
Tampon
Prion
Temperature (°C):121℃ Cycle type:B Sterilization time:30min Drying time:18min
Water Tank
Water tank group completely accessible and inspectionable for a perfect and complete cleaning as per the maintenance program and safeguard of the device.
3.5Liters Transparent open water quality monitoring
Water filling function Manual (Standard)/Automatic (Option) sterilizers, to facilitate filling operation, are equipped with a pump-operated filling system featuring a level sensor that stops water filling if the tank is full.
Built-in water quality detection (Option)
Thanks to the built-in quality detector, it can provide better water source for the sterilizer and extend the use time of the sterilizer.
Average water consumption:
Novo Pro18L: 0.15L(Min)0.26L(Max) Novo Pro 23L:0.17L(Min)0.31L(Max)
The Door
Newly designed door is easy to open and close with one hand. Safety locker with double safety locking mechanism. Cycle will not start if the door is open or not properly locked. Safety locking device prevents door from opening until chamber pressure reaches atmospheric pressure.
Mechanical Lock
Sensor Switch
Pressure lock
Pressure lock to prevent the door from opening while the cycle is running.
Carrier & Tray
The carrier can be loaded with up to 5 trays or 3 trays, rotated by 90°.
Steel wire carrier
Steel wire tray
Aluminium bracket tray
F.g.: mirror, probe, etc.
Instruments management assistant (Option)
F.g.: mirrors, probes etc. 180 X125 X20mm
Technical Specifications
Electrical supply
220-240 VAC-50/60Hz, single-phase
Nominal voltage
220V, 50Hz
Max current
10A
Max. altitude
2000 asl, More than 2000m call service
Max Working Pressure
2.5 Bar(250 kPa)
Min Working Pressure
-0.9 Bar(-90 kpa)
Min atmospheric pressure
0.7bar
Max Temperature
<145°C
Overall dimensions
585x438x405mm(Novo Pro18L) 685x438x405mm(Novo Pro 23L)
Max weight (fully loaded)
50 kg(Novo Pro 18L) 60kg(Novo Pro 23L)
Pressure safety valve
2.45 bar(符合YY0154-2013和YY/T0157-2013)
Vacuum
-0.08Mpa
Sound power levels
< 80 DB
Sterilizer chamber (Total volume)
245 mm x D355 mm(Novo Pro 18L) 245 mm x D445 mm(Novo Pro 23L)
Usable chamber volume
198 mm x 204mm x 319mm(Novo Pro 18L) 198 mm x 204mm x 385mm(Novo Pro 23L)
Bacteriological filter
The filtration efficiency of particles above 0.3um be no less than 99.5%
Water Quality
EC(conductivity<15uS/cm)
Average water consumption
Novo Pro 18L:0.15L(Min) 0.26L(Max) Novo Pro 23L:0.17L(Min) 0.31L(Max)
Tank volume
Clean water tank 3.5L
Conformity
Medical Device Directive (MDD) YY/T0646-2015
Product Information
| Manufacturer | Ningbo Joident Electronics Technology Co., Ltd |
|---|---|
| Vacuum | >-0.08Mpa |
| Door Type | Hand-operated with double safety locking mechanism |
| Cycle Types | S (Solid load) and B (Hollow bodies/wrapping) |
| Max Current | 10A |
| Max Altitude | 2000 asl |
| Traceability | SD card Log or thermal printer (Built-in/External) |
| Water Filling | Manual (Standard) or Automatic (Option) |
| Water Quality | EC (conductivity<15uS/cm) |
| Chamber Volume | 29L (Novo Pro 29L Plus variant) |
| Cooling System | Wind cooling super window (260x142mm, 73 layers heat radiating aluminium) |
| Max Temperature | <145°C |
| Nominal Voltage | 220V, 50Hz |
| Sterilizer Type | Autoclave/Steam Sterilizer |
| Carrier Capacity | Up to 5 trays or 3 trays rotated by 90° |
| Electrical Supply | 220-240 VAC-50/60Hz, single-phase |
| Monitoring System | Intelligent monitoring and diagnosis system |
| Sound Power Level | < 80 DB |
| Number Of Programs | 11 Programs and tests |
| Water Tank Capacity | 3.5 Liters |
| Max Working Pressure | 2.5 Bar (250 kPa) |
| Min Working Pressure | -0.9 Bar (-90 kpa) |
| Pressure Safety Valve | 2.45 bar |
| Water Quality Detection | Built-in (Option) |
| Sterilization Temperature Range | 121°C and 134°C |
| Instruments Management Assistant | Option available |
| Bacteriological Filter Efficiency | ≥99.5% for particles above 0.3um |