Novo Pro 23L

Ningbo Joident Electronics Technology Co., Ltd · source

Dental steam sterilizer

Combining the experience of modern art and minimalist shape design, it is seamless from inside to outside. Our design size can be used for any occasion, so that you can experience the charm of modern art.

Designed to make your life easier, save space and guarantee high efficiency
Intelligent monitoring and diagnosis system

Ensures a constant control and monitoring of the whole operating system of the sterilizer. When faults occur, it will find the failure parts sectionally, and shows the fault message and simple solution direct which makes the after-sales message is more detailed and the maintenance is more convenient. This device behaves like a "real technician" with real-time diagnostic and intervention capability.

Simplified traceability

The data of every sterilization cycle are traceable, in compliance with the applicable standards in force, thanks to the SD card Log or thermal printer (Built-in/External).

Pre-heating system

Preheating system with stand-by for minimum temperature maintenance and consequent time reduction of all the sterilization cycles.

Wind cooling super window

260x142mm large cooling area, 73 layers heat radiating aluminium sheet, 18 radiating pipe, to ensure the hot steam water changes to the cold water in a few seconds.

About Novo Pro

Sterilizers and accessories that help dentists and their assistants to always ensure the highest levels of safety and hygiene in their practice, in full compliance with applicable international regulations. Assures to sterilise unwrapped solid tools and porous products, small porous items, pots and containers, single-wrapped or multiple-layer wrapped products.

Features
  • Multi-language operating system
  • Intelligent diagnosis system
  • 11 Programs and tests
  • Accurate touch interface Simplicity Innovation Practically
  • Only three clicks, automatically complete sterilization cycle
Completely Automatic Cycles

All Programs are completely automatic and all phases are managed by advanced card equipped with a powerful microprocessor. Each phase (vacuum, preheating, exposure time, drying) is monitored, backed up and managed automatically. There is no human intervention in cycle operation.

Sterilization Programs

Quick Load Programs (134°C)
Solid load
  • Temperature: 134°C
  • Cycle type: S
  • Sterilization time: 10min
  • Drying time: 9min
Quick (Emergency sterilization only)
  • Temperature: 134°C
  • Cycle type: S
  • Sterilization time: 4min
  • Drying time: 4min
Hollow bodies
  • Temperature: 134°C
  • Cycle type: B
  • Sterilization time: 5min
  • Drying time: 18min
Multiple wrapping
  • Temperature: 134°C
  • Cycle type: B
  • Sterilization time: 18min
  • Drying time: 18min
Pre-set Programs (121°C)
Solid load
  • Temperature: 121°C
  • Cycle type: S
  • Sterilization time: 30min
  • Drying time: 9min
Glass
  • Temperature: 121°C
  • Cycle type: S
  • Sterilization time: 20min
  • Drying time: 9min
Hollow bodies
  • Temperature: 121°C
  • Cycle type: B
  • Sterilization time: 20min
  • Drying time: 18min
Tampon (Prion)
  • Temperature: 121°C
  • Cycle type: B
  • Sterilization time: 30min
  • Drying time: 18min
Water Tank
  • Tank volume: Clean water tank 3.5L, Sewage tank 1.7L
  • Water filling: Manual (Standard) / Automatic (Option)
  • Built-in water quality detection (Option)
  • Average water consumption: 0.17L (Min) 0.31L (Max)
  • Water Quality: EC (conductivity < 15uS/cm)
The Door
  • Newly designed door is easy to open and close with one hand
  • Safety locker with double safety locking mechanism
  • Cycle will not start if the door is open or not properly locked
  • Safety locking device prevents door from opening until chamber pressure reaches atmospheric pressure
  • Mechanical Lock
  • Sensor Switch
  • Pressure lock to prevent the door from opening while the cycle is running
Carrier & Tray

The carrier can be loaded with up to 5 trays or 3 trays, rotated by 90°.

Steel wire carrier (23L)
  • Dimensions: 410 × 205 × 200 mm
Steel wire tray (23L)
  • Dimensions: 380 × 190 × 20 mm
Instruments management assistant (Option)
  • For mirrors, probes, etc.
  • Dimensions: 205 × 140 × 32 mm
Instruments management assistant (Option)
  • For mirrors, probes, etc.
  • Dimensions: 180 × 125 × 20 mm
Technical Data
Electrical Supply
  • Electrical supply: 220-240 VAC-50/60Hz, single-phase
  • Nominal voltage: 220V, 50Hz
  • Max current: 10A
Environmental Conditions
  • Max. altitude: 2000 asl (More than 2000m call service)
  • Max Working Pressure: 2.5 Bar (250 kPa)
  • Min Working Pressure: -0.9 Bar (-90 kpa)
  • Min atmospheric pressure: 0.7 bar
  • Max Temperature: <145°C
Physical Dimensions
  • Overall dimensions: 685 × 438 × 405 mm (Novo Pro 23L)
  • Max weight (fully loaded): 60 kg (Novo Pro 23L)
  • Sterilizer chamber (Total volume): 245 mm × D445 mm (Novo Pro 23L)
  • Usable chamber volume: 198 mm × 204 mm × 385 mm (Novo Pro 23L)
Performance
  • Pressure safety valve: 2.45 bar (符合YY0154-2013和YY/T0157-2013)
  • Vacuum: >-0.08 Mpa
  • Sound power levels: < 80 DB
  • Bacteriological filter: The filtration efficiency of particles above 0.3um be no less than 99.5%
Average Water Consumption
  • Novo Pro 23L: 0.17L (Min) 0.31L (Max)
Compliance Standards
  • 93/42/EEC Medical Device Directive (MDD)
  • EN 13060 Small Steam Sterilizer
  • IEC 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use, general requirements
  • IEC 61010-2-040 Safety requirements for electrical equipment for measurement, control and laboratory use particular requirements for autoclaves using steam for the treatment of medical materials and for laboratory processes
  • EN 61326 Electrical equipment for measurement, control and laboratory use: EMC requirements

Informations produit

FabricantNingbo Joident Electronics Technology Co., Ltd
TypeDental steam sterilizer
ModèleNovo Pro 23L
Vacuum>-0.08 Mpa
CaractéristiquesMulti-language operating system, Intelligent diagnosis system, Completely automatic cycles, Pre-heating system, Wind cooling super window (260×142mm)
Door TypeMechanical Lock with Sensor Switch and Pressure lock
Max Current10A
CertificationEN 13060, IEC 61010-1, IEC 61010-2-040, EN 61326, 93/42/EEC (Medical Device Directive)
Water FillingManual (Standard) / Automatic (Option)
Water QualityEC (conductivity <15μS/cm)
Chamber Volume23L
Max Temperature<145°C
Nominal Voltage220V, 50Hz
Safety FeaturesDouble safety locking mechanism, pressure lock, cycle cannot start if door not properly locked
Carrier Capacity5 trays or 3 trays rotated by 90°
Electrical Supply220-240 VAC-50/60Hz, single-phase
Operating Programs11 programs (134°C and 121°C cycles)
Overall Dimensions685 × 438 × 405 mm
Sewage Tank Volume1.7L
Sound Power Levels< 80 DB
Max Working Pressure2.5 Bar (250 kPa)
Min Working Pressure-0.9 Bar (-90 kpa)
Clean Water Tank Volume3.5L
Average Water Consumption0.17L (Min) - 0.31L (Max)
Max Weight (fully Loaded)60 kg
Steel Wire Tray Dimensions380 × 190 × 20 mm
Steel Wire Carrier Dimensions410 × 205 × 200 mm
Built In Water Quality DetectionOption available
Bacteriological Filter Efficiency≥99.5% for particles >0.3μm