PrepClean Buffing Compound Remover
L&R Manufacturing Company · #078 · source
Concentrated formula provides complete cleaning of buffing compounds, including rouge and tripoli, thoroughly removing them from all surfaces. Effective and safe. For use in an ultrasonic cleaner.
Directions for Use
- This product is a concentrate. Dilute 1 part solution with 12 parts water. Can be diluted with up to 33 parts water.
- Use directly in an ultrasonic cleaner.
- To clean, place parts in accessory basket. Insert basket into ultrasonic tank filled 2/3 full with properly diluted PrepClean Buffing Compound Remover.
- Operate ultrasonic cleaner for 5-10 minutes depending on volume and amount of contaminant to be removed. Normal operating temperature is 130°F (54°C).
- After cleaning, rinse thoroughly under running water.
- DO NOT USE ON ALUMINUM.
Informations produit
| Fabricant | L&R Manufacturing Company |
|---|---|
| Type | Concentrated cleaning solution |
| Application | For use in an ultrasonic cleaner |
| Temperature | 130°F (54°C) |
| Restrictions | DO NOT USE ON ALUMINUM |
| Cleaning Time | 5-10 minutes |
| Cleaning Time | 5-10 minutes |
| Dilution Ratio | 1 part solution with 12 parts water (can be diluted with up to 33 parts water) |
| Dilution Ratio | 1 part solution with 12 parts water (can be diluted up to 33 parts water) |
| Special Instructions | DO NOT USE ON ALUMINUM |
| Température de fonctionnement | 130°F (54°C) |