SIRAY PLUS

Zhuhai Siger Medical Equipment Co., Ltd. · source

SIRAY PLUS

Key Features

» High frequency DC constant voltage control technology » Better image quality » Compared to traditional AC generators, it greatly reduces the radiation dose » Extend the service life of the X-ray generator » The amount of radiation output is not affected by voltage fluctuations

High frequency DC constant voltage control technology

◎ Better image quality. ◎ Greatly reduces the radiation dose. ◎ Extend the service life of the X-ray generator. ◎ The amount of radiation output is not affected by voltage fluctuations.

High quality image

◎ Advanced high frequency and constant voltage DC generator. ◎ High quality DC X-ray tube. ◎ 0.4mm focal spot delivers sharp images in high resolution. ◎ The selectable kV values (60kV/65kV/70kV) and mA values (2mA / 7mA) provide excellent images for diagnosis and research.

Stable and reliable
Convenient imaging parameter settings

Based on abundant clinical data, Siray / Siray Plus provides 48 pre-programmed settings for different exposure value combinations, according to the exposure region, patient size, imaging mode, etc.

8 exposure region can be chosen on the control panel
Expert parameter setting

Professional users can preset various parameters and save to the corresponding exposure program. It is also possible to adjust appropriate parameters before exposure according to actual needs.

◎ The exposure time can be adjusted between 0.02 and 2 seconds. ◎ 60kV, 65kV and 70kV anode pressure is selectable. ◎ 2mA and 7mA anode current is selectable. ◎ Adult / child mode selection is available. ◎ Film-based mode, phosphoric mode and digital imaging mode selection is available.

Flexible movement and drift-free positioning

Accurate positioning is necessary to ensure high quality images. The steady arm of SIRAY PLUS X-ray Units apply engineering mechanics design to allow easy and accurate targeting.

Scientific weight ratio makes sure the smooth rotation and positioning without drifting.

Scale for the cone angle make the positioning easy and accurate.

Installation options

Four mounting methods are available according to actual clinic environment.

Informations produit

FabricantZhuhai Siger Medical Equipment Co., Ltd.
ModesFilm-based, phosphoric, digital imaging
Kv Values60kV/65kV/70kV
Ma Values2mA / 7mA
Focal Spot0.4mm
Anode Current2mA and 7mA selectable
Exposure Time0.02 - 2 seconds
Patient ModesAdult/child selection available
Anode Pressure60kV, 65kV, 70kV selectable
Generator TypeHigh frequency DC constant voltage
Exposure Regions8 options
Installation OptionsFour mounting methods
Pre Programmed Settings48 combinations